My own solar photovoltaic system Fronius

Last updated on: 2017-02-04

Accomplissements
Irradiance
Irradiation



Relevant figures:
  Total production     30.3 MWh     Specific yield     1162 kWh/kWp (2016)     Feed-in money     17291 €     ROI     108 %     Average daily energy production     10.8 kWh     Average week     76.4 kWh     Average month     329.3 kWh     Best day     2013-06-24     21.5 kWh     7 Wh/Wp     Best month     July 2013     536 kWh     180 Wh/Wp     Days monitored     2854     CO2 savings     5460 Kg  



logo BPlogo EDFlogo ministère logo région



Technical data:
  Power     2970 Wp     Latitude     43.588144     Longitude     3.761561     Orientation     South -10°     Tilt     18°     FIT     0.57 €     Total cost     16 k€     Cell area     20.25 m²     Module area     22.65 m²     Module specs     Inverter specs     CO2 emissions     Simulation  


Overview:

Monthly energy production in 2009


Comment: In April, the datalogger did not work for a few days, Monitoring started mid January

Monthly energy production in 2010


Monthly energy production in 2011


Comment: On June 4th 2011, a thunderstorm opened the AC breaker which in turn prevented the inverter from connecting to the grid. The breaker was manually closed on July 12th 2011 (unfortunately losing 39 days)

Monthly energy production in 2012


Comment: the datalogger probably had an issue, as the total yield in 2012 must be similar to that of 2011, as indicated by the grid operator's measurements

Monthly energy production in 2013


Comment:

Monthly energy production in 2014


Comment:

Monthly energy production in 2015


Comment:

Monthly energy production in 2016


Comment:
Detailed graphs below:

Best month energy production (July 2013, 536 kWh)


Worst month energy production (December 2015, 107 kWh)


Best week energy production (from 2014-05-12 to 2014-05-18, 139 kWh)


Worst week energy production (from 2009-12-21 to 2009-12-27, 20 kWh)


Best day energy production (Monday June, 24th 2013: 21.5 kWh)